Bosch Dryer E06 Error: Heating Element Fault
What Does Bosch Dryer Error Code E06 Mean? Error code E06 on a Bosch dryer indicates the heating element circuit has failed. The dryer tumbles but produces no heat, so clothes remain wet. Common Causes A burned-out heating element is the most common cause. A blown thermal fuse (often caused by previous overheating from lint […]
Quick Assessment
Answer to continue safely
Is it safe to keep using?
Maybe. The dryer is safe but won't dry clothes. You can use it as an air-dry tumble, but it will be very slow.
Can I reset the code?
No. E06 indicates a hardware failure. A reset will not restore the heating element.
When to stop immediately?
Stop if you notice: No heat at all from the exhaust, Burning smell.
Symptoms You May Notice
No heat produced
The drum turns but air coming out is room temperature — no warming at all.
Clothes stay wet after full cycle
Laundry is as damp after the cycle as when it went in.
Possible Causes
Burned-out heating element
The resistive heating element has developed an open circuit.
Requires ProfessionalBlown thermal fuse
A thermal fuse in the heater circuit has tripped and needs replacement.
Requires ProfessionalFaulty heating relay
The relay on the control board that powers the heater has failed.
Requires ProfessionalSafe Checks You Can Do
-
1
Feel the exhaust air
Start the dryer and hold your hand at the exhaust vent. Air should be warm within 5 minutes.
If air is cool, the heater is not functioning.
-
2
Check the circuit breaker
Verify the dryer circuit breaker has not partially tripped. Reset it fully.
A partially tripped breaker can power the motor but not the heater.
When to Call a Professional
Contact a qualified technician if:
- Heating element has no continuity
- Thermal fuse has tripped
- Control board relay is burned
Need Professional Help?
Find qualified technicians in your area for proper diagnostics and repair.
Dryer Repair Service Schedule Appointment